Test rig for CO2 liquefaction at TU Dresden
Short description

Flue Gas Liquefaction Facility at TU Dresden
Flue Gas Liquefaction Facility at TU Dresden

  • Test facility for flue gas drying and compression.
  • In connection with the Pulverised Fuel Combustion Test Facility, therefore a direct liquefaction and continous distillation in the 'oxyfuel' mode or filling of gas cylinders is possible.
  • Heated feed to avoid condensate.
  • Compressed air driven piston compressor for initial compression.
  • Additional filter road for dust removal.
  • Drying with a hollow fibre membrane module using compressed and dried air.
  • Compression by an electrical driven piston compressor.
  • Condensation by a double pipe heat exchanger with cocurrent or countercurrent principle.
  • Phase separator with inspection glass for separation of lower boiling residual gas.
  • Compressed air driven condensate pump for feeding the Rectification Column Test Facility or the gas cylinder stock.
Plant components
1: Crude gas inlet 7: Compressed air dryer
2: Initial Blower 8: Double pipe condenser
3: Filter road 9: Phase separator with inspection glass
4: Compensating reservoir 10: Condensate pump
5: Hollow fibre membrane module 11: Gas cylinder stock with electronic balance
6: High pressure compressor 12: Liquefied clean gas outlet

Datasheet
Raw gas volume flow: 5...10 m³/h
Raw gas inlet temperature: 120...220 °C
Discharge pressure: 40...80 bar infinitely variable
Condenser: Double pipe: 6/12x1 mm
Outlet temperature: ca. 1 °C (till -90 °C possible)
Material: Stainless steel
Gas cylinder stock: 2x 50 l (separate filling possible)
Operation and measurements

System Control

  • All pressure levels required for the operation are manually adjustable by flow-control valves, pressure regulators or rather differential pressure regulators.
  • For safety reasons and control there are shut-off valves, pressure relief valves, thermometers as well as manometers between all main components.
  • Liquefaction pressure and temperature are set up by hand. The result can be supervised through an inspection glass.

Measurement data logging

  • For measurement data logging and analysis the facility has digital equipment for temperature as well as pressure measurement before and after every single component.
  • The gas analysis can take place after partial decompression of the product streams or in the lab using mobile sample containers.