Rectification Column for SO2-Separation
Short description
Rectification Column Test Facility at TU Dresden
Rectification Column Test Facility at TU Dresden
  • Rectification column (counter current distillation) with integrated evaporator and condenser
  • For separation of SO2 and if necessary, further gaseous impurities of oxyfuel flue gas (alternative cleaning method for CO2)
  • Operating method: continuously or batch operation
  • Feeding and product extraction on every bubble tray possible
  • Heating and cooling capacity individually adjustable
Datasheet
Dimensions: Inner diameter: 129.7 mm (column)
Height of the column: 1622 mm
Overall height: 4350 mm
Materials: Stainless steel 1.4541 (column and internals)
Steel-covered Teflon-tube
Number of columns: 8 bubble trays
flow rate: 6...8 l/h fluid CO2
Operating parameters: max. 45 bar
Vapor outlet: 3...4 °C
Condensate outlet: 115...120 °C
Heating capacity: max. 3.0 kW
Cooling capacity: circa 3.2 kW at -10 °C
Product purity: 99.97 % vol. CO2 (overhead product)
99.12 % vol. SO2 (bottom product)
More illustrations
Rectification Column Test Facility at TU Dresden
Rectification Column Test Facility at TU Dresden
Rectification Column Test Facility at TU Dresden