Rectification Column Test Facility at TU Dresden
|
-
Rectification column (counter current distillation) with integrated evaporator and condenser
-
For separation of SO2 and if necessary, further gaseous impurities of oxyfuel flue gas (alternative cleaning method for CO2)
-
Operating method: continuously or batch operation
-
Feeding and product extraction on every bubble tray possible
-
Heating and cooling capacity individually adjustable
|
Dimensions:
|
Inner diameter: 129.7 mm (column)
Height of the column: 1622 mm
Overall height: 4350 mm
|
|
Materials:
|
Stainless steel 1.4541 (column and internals)
Steel-covered Teflon-tube
|
|
Number of columns:
|
8 bubble trays
|
|
flow rate:
|
6...8 l/h fluid CO2
|
|
Operating parameters:
|
max. 45 bar
Vapor outlet: 3...4 °C
Condensate outlet: 115...120 °C
|
|
Heating capacity:
|
max. 3.0 kW
|
|
Cooling capacity:
|
circa 3.2 kW at -10 °C
|
|
Product purity:
|
99.97 % vol. CO2 (overhead product)
99.12 % vol. SO2 (bottom product)
|
|
Rectification Column Test Facility at TU Dresden
|